Objectives/Hypothesis
A wide variety of drug‐induced sleep endoscopy (DISE) scoring systems has been used to evaluate sites of upper airway obstruction in children and adults; however, a universally accepted DISE scoring system dedicated to children has not been developed. We evaluated the utility of DISE scoring systems in the assessment of obstructive sleep apnea (OSA) using a single cohort of pediatric patients.
Study Design
Retrospective chart review.
Methods
The medical records of surgically naïve–healthy children with OSA who had undergone DISE were reviewed. Information about demographics, past medical history, and severity of OSA were obtained. A literature review was conducted to identify DISE scoring systems used in children with OSA. Recordings of DISE were analyzed without knowledge of patient information and severity of OSA. The effect of age, obesity, severity of OSA, and oxygen nadir on DISE score was assessed.
Results
Sixty‐eight patients (46 male, 22 female, age range: 19 months–18 years) were included. Forty‐three patients were obese and 25 were nonobese. The severity of OSA was mild in 12 patients, moderate in 13 patients, and severe in 43 patients. DISE scoring systems did not document differences among the groups of patients with mild OSA, moderate OSA, and severe OSA (P > .05). DISE scores were not different among the studied age and weight categories (P > .05).
Conclusions
The DISE scoring systems did not show differences in DISE scores in surgically naïve–healthy children with varying age, weight, and OSA severity categories. Our findings provide preliminary evidence for the need of a universally applicable pediatric DISE scoring system for OSA.
Level of Evidence
4 Laryngoscope, 2019
from #Head and Neck by Sfakianakis via simeraentaxei on Inoreader http://bit.ly/2CISGlE
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου
Σημείωση: Μόνο ένα μέλος αυτού του ιστολογίου μπορεί να αναρτήσει σχόλιο.