Abstract
Purpose
To compare the dose calculation accuracy of plans done on a CT density-assigned MR image set for hypofractionated stereotactic radiotherapy (HSRT) using volumetric modulated radiation therapy containing non-coplanar beams.
Methods
Eighteen patients diagnosed with schwannoma treated with HSRT were selected retrospectively. These patients underwent planning CT (pCT) for radiation therapy (RT) and contrast-enhanced three-dimensional fast-spoiled gradient-echo image (3D FSPGR) to assist tumor delineation. CTplan is plan done on pCT. The structures body, bone, and air are contoured exclusively on MR image and assigned Hounsfield units of 25, + 1000, and − 1000, respectively. This is termed as MRCT. After registration, original plans from pCT are pasted on the MRCT. Dose calculation is done in two ways: (1) with preset MU values (DDC) and (2) with optimization (OPT_DC). Conformity indices and Dmax and D0.5cc of brainstem, gamma agreement index and correlation coefficient are analyzed. ANOVA test is carried out to find the significance of difference between plans.
Results
The mean deviations of Dmax and D0.5cc of brainstem for CTplan versus DDC are 2.49% and 1.45% respectively. The mean deviations of Dmax and D0.5cc of brainstem for CTplan versus OPT_DC are − 1.56% and − 1.97%, respectively. Mean deviations of conformity index for DDC and OPT_DC are 0.84% and 0.89%, respectively. No significant difference was found with ANOVA test.
Conclusion
Results show that there is no difference between plans generated with actual CT data and MRCT data. Thus MR scans could be employed for radiation planning provided the verification image is available. This gives us confidence to reduce treatment margins where image registration process is avoided.
from #Head and Neck by Sfakianakis via simeraentaxei on Inoreader https://ift.tt/2R6r7vZ
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου
Σημείωση: Μόνο ένα μέλος αυτού του ιστολογίου μπορεί να αναρτήσει σχόλιο.